Apc Hyperterminal Software

Posted on by

Kermit Software Source Code Archive. Most recent update. Mon Aug 2. 2 1. 4 5. Index to table TOP. Welcome to what might be the biggest collection on earth of software. This page. provides, for the first time, convenient Web HTTP access to all the. Kermit software archive. Apc Hyperterminal Software' title='Apc Hyperterminal Software' />Each program can be downloaded as. Unix or a Zip. archive for Windows, VMS, and other platforms that have Unzip, and if FTP. In many cases manuals are also available. PDF, others as plain text. The once common. Microsoft Word or Help programs others have been left as they were. Here. are some common ones. E Mail message, plain text. Hints and tips, plain text. Plain text encoding of a binary file. A somewhat more compact plain text encoding of a binary file. Usually a VMS command file or DCL procedure plain text. Scribe markup language source for documentation, plain text. Document for printing on a Post. Script printer. Document for viewing with PDF reader or for printing. The term extended ASCII EASCII or high ASCII refers to eightbit or larger character encodings that include the standard sevenbit ASCII characters, plus additional. I have an APC SMARTUPS 3000 with a WebSNMP Network Management interface. I need to reset the username and password. I have tried every recommended procedure. Many more extensions can be found, for example for source code. PDF and Post. Script are plain text, unless they are in the archives or bin directories. More about the Kermit archiveafter the big. F00_debug_5F00_connection.jpg' alt='Apc Hyperterminal Software' title='Apc Hyperterminal Software' />This website may contain content submitted by users and is for informational purposes only. APC by Schneider Electric shall have no responsibility for the accuracy. Manually Resetting an APC SmartUPS Battery Constant After New Battery Replacement Mar 27, 2011, 103 PM 0500. Kermit Software Source Code Archive Web Access Frank da Cruz Most recent update Mon Aug 22 145205 2011 Index to table. Transmit 4 Serial Number Mac here. Первое знакомство с оборудованием Cisco. Как подключиться к Cisco. Что делать с циской Enumeration In. NET it is possible to assign values to names with the structure GroupName. Member like this Public Enum MyColors MistyRose HE1E4FF. Introduction The APCTM by Schneider Electric SmartUPS SURT192XLBP external battery pack XLBP connects to select APC by Schneider Electric Uninterruptible. If your browser refuses to show you a file because it cant find. Here are the programs in the Kermit software archive. In addition to. these, there are hundreds, perhaps thousands, of Kermit protocol. Reflexions, Crosstalk, Procomm, Hyperterminal. Kermit protocol is also. HP calculators. The Kermit Software Archive 1. Name. C Kermit is the most portable and long lived of all Kermit. It is also the basis for. Unix is an operating system family that comprises Linux, Free. BSD. Net. BSD, Mac OS X, HP UX, AIX, Solaris, SCO, and many others both. C Kermit is available for all of. There are approximately 7. C Kermit. Unix and about 1. Unix C Kermit binaries in the archive names. VMS, also known as Open. VMS, is a proprietary operating system. Digital Equipment Corporation DEC, which passed to Compaq and. Hewlett Packard HP. C Kermit is available for VMS versions old. VAX, Alpha, and IA6. Tar and Zip archive legend cku for Unix ckv for VMS cko for. OS2 ck. 9 for OS9 ckl for Stratus VOS ckc for all. C Kermit. cku. 21. C Kermit. cku. 20. C Kermit. cku. 20. C Kermit. cku. 20. C Kermit. Unix, VMS, Data General AOSVS, Stratus VOS, Plan 9 from Bell Labs. Microware OS9, Commodore Amiga. C Kermit. Unix, VMS, AOSVS, VOS, Plan 9, OS9, Amiga, IBM OS2. C Kermit. Unix, VMS, AOSVS, Plan. OS9, Amiga, Apple Macintosh. Apollo Aegis, Atari ST. C Kermit. cku. 18. C Kermit. Unix, VMS, OS2, OS9, Amiga, Apollo, Macintosh. C Kermit. Unix, VMS, OS9, Amiga, Apollo, Macintosh. C Kermit 4. 0. 5 Feb 1. D are. missing. The versions just below are Unix command line only. BSD Unix only single source file. BSD Unix, Amdahl UTS, VMS modular. Earlier versions of Unix Kermit are lost, but appear. Version 1 was a. single source file that was for 4. BSD only. Kermit Protocol for Embedding. Anyek. 17. tar. gzek. EKSW. eksw. 09. 4. G Kermit. All versions of Unix that have an ANSI C compiler. Kermit 9. 5. Kermit software for 3. Microsoft Windows and. ManualKermit 9. 5. Microsoft Windows 9. IBM OS2 Warp. k. MS DOS Kermit. MS DOS computers see list just below. MS DOS Kermit runs on the IBM PC and compatibles with MS DOS. PC DOS, or DR DOS, or under Microsoft Windows 3. Separate. versions were created for the following non IBM compatible PCs. ACT Apricot, DEC Rainbow, DECmate II and III, GRi. D Compass II. HeathZenith 1. HP Portable Plus, HP 1. HP 1. 50, Intel 3. Series with. i. RMX 8. RMX 2. 86, Macintosh with AST2. NEC APC, NEC APC III, NEC. PC9. 80. 1, Olivetti M2. PC, Sanyo 5. 50 MBC, Seequa Chameleon, TI Professional. VictorSirius 1, and the Wang PCAPC. PC Kermit or Kermit 8. MS DOS Kermit. DOS on the IBM PC and the HZ 1. Bootstrap. Receive only Kermit. Kermit book to type in and run to. Kermit program. MS DOS when all PCs had BASIC. The versions above are the big ones in terms of popularity, coverage, scope. From here down we go in approximately alphabetical order. Many of these are adaptations of early versions of the Kermit programs. IMPORTANT C Kermit is listed. This does. not necessarily mean that later versions do not work on those platforms. Ditto for G Kermit. Obviously not every single platform is listed for C Kermit or. G Kermit here because there are thousands of them. Even for modern. platforms click. C Kermit 9. 0. Kermit for Acorn computers. C Kermit. Acorn Cambridge Workstation with PANOS. Arthur Kermit. 1. C Kermit 4. C0. Acorn Archimides with RISC OS followon to Arthur. BBC Kermit. Acorn BBC Micro. B, B, B1. 28, and Master 1. Amdahl. Kermit for Amdahl mainframes. Amdahl made IBM 3. UTS was a UNIX virtual machine. VMCMS on an Amdahl or an IBM 3. Kermit 3. 70 could also be used on the same machine outside of. UTS. Several years later, C Kermit was adapted. UTS 2. 4 and UTSV. The Alpha Micro version of Kermit was featured in the book. Stan Kelly Bootle 1. Alpha Micro mc. 68. AMOSL and AMOS3. Kermit. C Kermit. cku. 19. Apple. Kermit for Apple computers. Apple II DOS, Pro. DOS. appleii. zipfile listwebsitemanual. Mac Kermit. Apple Macintosh. Manual Para Reparar Secadoras there. Mac Kermit 1. 98. Kermit programs. to have a graphical user interface GUI. Apple Macintosh AUX. C Kermit. Apple Macintosh Mac OS X. Atari. Kermit for Atari computers. Atari Home Computer DOS. Kermit. Atari ST GEMDOS. C Kermit. Atari ST GEMDOS. Burroughs. Kermit for Burroughs Mainframes. Burroughs B6. 80. CANDE. burroughs. Kermit 7. 80. 0. Burroughs 6. A Series. burroughs. Kermit Bur. Burroughs B7. CC Kermit. Chinese PCs with CCDOS. CDC. Kermit for the Control Data Corporation Cyber Supercomputer. CDC Cyber 1. 70 with NOS and NOSBE. CDC Cyber with NOS. CDC Cyber with NOS 2. C Kermit. CDC Cyber NOSVE VXVE. CIE Systems. Kermit for CIE 6. CIE 6. 20xx with Regulus. Commodore. Kermit for Commodore Computers. Kermit 6. 5. Commodore 6. C Kermit. ckc. 19. Computervision. Kermit for Computervision. Computervision minicomputer GCOS. Convergent. Kermit for Convergent Technologies CTOS. Convergent CTOS, Burroughs BTOS, Bull STARSYS. CPM 8. 0. Kermit 8. CPM 8. 0 and CPM 8. CPM 8. 0 2. 2, CPM 8. CPM 8. 5. cpm. 80. Kermit 8. 0 was one of the original Kermit programs, first written. Intertec. Superbrain and then made portable to many other CPM systems, all. Acorn BBC computer with Z8. Action Computer Enterprises Discovery. Ampro Little Board terminal required. Amstrad CPC 6. 64 and 6. Amstrad PCW 8. 25. Apple II with Z8. Softcard. British Telecom MerlinRair Black Box. Comart Communicator. DECmate II with CPM option. Digicomp Delphi 1. Generic CPM 3. 0. Generic CPM 2. 2. HeathZenith H8. 9. Hewlett Packard HP 1. Ithaca Intersystems. Micromint SB 1. 80. Morrow Decision I. Morrow Micro Decision I. NCR Decision Mate V. Northstar Advantage. Northstar Horizon. Northstar Horizon. Northstar Horizon. Ohio Scientific. PMC 1. Micromate. Research Machines 3. Z. Sanyo MBC 1. 10. TELCON Zorba portable. TRS 8. 0 model II. TRS 8. 0 model IV. Teletek Systemaster. Torch computers BBC B. US Microsales S1. Vector Graphics. Z 1. CPM 8. 5. Z8. 0MU development system on PC. Kermit 8. 6 for CPM 8. Concurrent CPM 8. CPM 8. 6 on the DEC Rainbow, Fujitsu Micro. Future FX2. 0FX3. NEC APC. Tektronix 4. VictorSirius 9. 00. Kermit 8. 6. VictorSirius 9. Kermit 8. 6. Concurrent CPM 8. Argos Pro PC, Daisy PCi, Fallon 2. FTS PCi. ICL PC2, ICL PC Quattro, Orion PCi. Cray. Kermit for Cray Supercomputers. Cray Research XMP or YMP or C9. UNICOS. cku. 21. 1. Network Management Card NMC Password Reset Procedure. Issue. Forgotten or lost Network Management Card NMC Password. This article applies to Network Management Card 1 and 2, as well as any devices that contain an embedded version of these cards such as a Rack Power Distribution Unit PDU or Rack Automatic Transfer Switch ATS. Product Line. Devices with an embedded WebSNMP Card include but are not limited to Environmental Monitoring Unit 1 AP9. THNetwork Management Card 1  AP9. AP9. 61. 8, AP9. 61. Devices with an embedded Network Management Card 1 include but are not limited to MeteredSwitched Rack PDUs AP7. Bonnie And Clyde 2013 Part One. XX, AP7. 9XX, Rack Automatic Transfer Switches AP7. XX, Environmental Monitoring Units AP9. AP9. 34. 0, Netbotz 2. Network Management Card 2 AP9. AP9. 63. 0CH, AP9. AP9. 63. 1CH, AP9. CHDevices with an embedded Network Management Card 2 include but are not limited to 2. G MeteredSwitched Rack PDUs AP8. XX, AP8. 6XX, AP8. XX, AP8. 9XX, Rack Automatic Transfer Switches AP4. XX, Certain AudioVideo Network Management Enabled products, Smart UPS Online SRT. Environment. All firmware versions unless otherwise notedAll serial numbers. Cause. The Network Management Cards administrator username andor password has been forgotten or lost and requires a special reset procedure in order to regain access. Resolution. These steps will require local access to the devices and require you to directly connect to it with the APC serial configuration cable. Browse the steps below for your device model in order to reset the administrators password. Note Connecting a non APC serial cable during the procedures below can cause unwanted erratic device behavior. WebSNMP Card Network Management Card 1 Procedure In addition, if you are trying to reset a password on a UPS that has more than one Smart. Slot accessory installed in it i. AP9. 60. 7 interface expander, it may be required to temporarily remove the other Smart. Slot accessories to gain direct serial access to the NMC console interface. Please reference that accessorys user guide on how to do that. It is also important to make sure that the accessories are installed in the correct order, referencing this document. Select a serial port at the local computer, and disable any service that uses that port. Refer to the chart below and obtain the correct communication cable for the Network Management Card 1 enabled device Device. Configuration Cable Part Number. Most UPSs with a DB 9 style serial port. DB 9 to DB 9Rack PDU AP8. XX, AP8. 6XX AP8. XX AP8. 9XX AP7. XX, AP7. XX9. 40 0. RJ 1. 2 to DB 91st Generation Rack Automatic Transfer Switch AP7. AP7. 70. 1, AP7. 72. DB 9 to DB 92nd Generation Rack Automatic Transfer Switch AP7. XX, excluding 1st Generation SKUs9. RJ 1. 2 to DB 94th Generation Rack Automatic Transfer Switch AP4. XX9. 40 0. 14. 4 RJ 1. DB 9Netbotz 2. 00Environmental Monitoring AP9. AP9. 34. 0, AP9. 32. DB 9 to DB 9Rack Air Removal Unit ACF4. ACF4. 029. 40 0. DB 9 to DB 9. Indicates the device uses NMC2 password reset procedure. Connect the serial cable to the selected port on the computer and to the configuration port at the UPSNetwork Management Card Embedded device. Run a terminal program such as Hyper. Terminal and configure the selected port as follows, depending on your device model type refer to the users manual if the device is not listed below Device. COM Port Settings Most UPSs with a DB 9 style serial port. Rack PDU 1. G and 2. G9. 60. 0 bps, 8 data bits, no parity, 1 stop bit, and no flow control. Generation Rack Automatic Transfer Switch AP7. NMC configuration refer to users manual for more information. Generation Rack Automatic Transfer Switch AP7. XX, except AP7. 75. Generation Rack Automatic Transfer Switch AP4. XX9. 60. 0 bps, 8 data bits, no parity, 1 stop bit, and no flow control. Netbotz 2. 00Environmental Monitoring AP9. AP9. 34. 0, AP9. 32. Rack Air Removal Unit ACF4. ACF4. 029. 60. 0 bps, 8 data bits, no parity, 1 stop bit, and no flow controlIndicates the device uses NMC2 password reset procedure. For three phase UPSs, it will be necessary to remove the communication cable from the port labeled Display that connects to the Power. View display prior to completing this reset procedure. Press ENTER, repeatedly if necessary, to display the User Name prompt. If you are unable to display the User Name prompt, verify the following. The serial port is not in use by another application. SCROLL LOCK is offdisabled. The terminal settings are correct as specified in step 3. The correct cable is being used as specified in step 2. Press the Reset button once. The Status LED will flash rapidly almost immediately while alternating between orange and green. AP9. Press the Reset button again a second time immediately while the LED is rapidly flashing which will cause the LED to then go off in order to reset the User Name and Password to their defaults temporarily the default User Name and password are both apc. Press ENTER as many times as necessary to redisplay the User Name prompt, then use the default, apc, for the user name and password. If you take longer than 3. User Name prompt is redisplayed, you must repeat step 5 and log on again. From the Control Console menu, select System, then User Manager. Select Administrator, and change the User Name and Password settings, both of which are now apc. Press CTRLC, log off, reconnect any serial cable you disconnected, and restart any service you disabled. Note For Network Management Cards running lower than version 2. AP9. 60. 6, step 6 the second reset press will not be necessary. Network Management Card 2 Procedure. Please note On v. X. X firmware, the Super User or Administrator level accounts can reset other Administrator, Device, Read Only, and Network Only user passwords. This procedure may not be required if the Super User password or at least one set of Administrator credentials are known. You can use a local computer that connects to the Network Management Card through the serial port to access the command line interface. This port is labeled Console and is on the Network Management Card itself. Youll also need to press the pinhole reset button access is located on the front of the Network Management Card to the right of the Ethernet jack. Select a serial port at the local computer, and disable any service that uses that port. Connect the provided serial cable APC part number 9. Network Management Card. Run a terminal program such as Hyper. Terminal and configure the selected port for 9. Press ENTER, repeatedly if necessary, to display the User Name prompt. If you are unable to display the User Name prompt, verify the following. The serial port is not in use by another application. SCROLL LOCK is on. The terminal settings are correct as specified in step 3. The correct cable is being used as specified in step 2. Press the Reset button once please note, sometimes aligning a paper clip or similar to the pinhole reset button can be difficult. It is suggested to hold the paper clip or similar device towards the top of the reset button hole and press gently until the alignment is made. Wait 5 7 seconds the Status LED will be off while you wait and then after that period of time, the Status LED will flash rapidly while alternating between orange and green.